Refrigeration Digital Manifold HVAC Gauge System Kit Meter Vacuum Pressure Test

$ 54.9

Availability: 24 in stock
  • EAN: Does not apply
  • Refund will be given as: Money Back
  • MPN: JP169101
  • Manifold Purpose: Charging
  • All returns accepted: Returns Accepted
  • Model: DY517
  • Gauge Features: Digital
  • Restocking Fee: No
  • Return shipping will be paid by: Buyer
  • Vacuum Units: Micron
  • Gauge Purpose: Pressure
  • Type: Manifold, Gauge & Hose Set
  • Item must be returned within: 60 Days
  • Brand: DY
  • Condition: New
  • UPC: Does not apply

    Description

    DY517 HVAC Digital Manifold Gauge Air Condition A/C Refrigerant Scale Set US
    Description
    HVAC Vacuum Leakage Dector Pressure Gauge Refrigeration Manifold Digital Tester
    JP169101
    Product specifications:
    Pressure test: gauge pressure
    Pressure test unit: Kpa; Mpa; bar; inHg; PSI.
    Pressure test range: 0 Kpa – 6000 Kpa
    Pressure test resolution: 1 Kpa
    Pressure test accuracy: +/- 0.5 %(FS)+ 5dgt
    Pressure overload limit: 10000 Kpa (10 Mpa; 100 bar;)
    Vacuum test: relative vacuum
    Vacuum test unit: Kpa; Mpa; bar; inHg; PSI.
    Vacuum test range: -101 Kpa – 0 Kpa
    Vacuum test resolution: 1 Kpa
    Temperature test unit: °C (Celsius), °F (Fahrenheit)
    Temperature test range: -40°C–150°C (-40°F–302°F)
    Temperature test resolution:
    0.1°C (-40°C–99.9°C), 1°C (100°C–150°C)
    0.1°F (-40°F–99.9°F), 1°F (100°F–302°F)
    Temperature test accuracy: +/- 0.5 °C + 2dgt +/- 0.9 °F + 2dgt
    Built-in 89 kinds of refrigerant NIST: According to American NIST standard
    Power Supply: 4 X 1.5V (SIZE.AA / LR6) Battery not include
    Dimensions: 170*110*50mm weight: 950g
    Features:
    The intelligent electronic refrigerant group instrument is an Lauxiliary instrument for the installation, testing and maintenance of refrigeration equipment such as air conditioners and cold storage. The instrument has double pressure test, dual temperature test (need test clip,not include), digital readout, multi-unit switching, multi-mode function and built-in refrigerant database. The instrument uses high-strength engineering plastics and flexible non-slip silicone design, the whole machine is solid and comfortable to hold. Built-in 32-bit digital processing unit and high-precision data acquisition unit, high data and stability. Large-size liquid crystal display, LCD backlight support, data display clear and easy to read, convenient light operation. Long-life valve switch, 1/4-inch standard interface design to ensure that the instrument's durability and versatility.
    The instrument can measure double pressure (gauge pressure) at the same time, as well as dual temperature measurement (need test clip,not include), with automatic multi-unit pressure conversion, automatic conversion of temperature Celsius / Fahrenheit, to facilitate different needs. Built-in 89 kinds of refrigerant pressure-evaporation temperature database, also calculate the subcooling superheat, to facilitate direct reading of operating process data. Also it tests percentage of vacuum measurement; pressure leak measurement, leak time speed record. It is deserved to have this multi-functional, accurate and simply operated digital manifold let you do the job right.
    EC/EN61010-1 safety standards for design and production.
    1) The pressure measured by the digtal manifold pressure tester is gauge pressure.
    2) Pressure testing ranges from -101Kpa to 6Mpa (-0.1bar to 60bar).
    3) The limit pressure is 10 Mpa (100 bar).
    4) The maximum operating pressure of standard hose is 600 PSI ( approximate 4.13 Mpa, 41.3 bar ). The limit pressure is 3000 PSI approximate 20.68 Mpa, 206.8 bar ).
    5) Please confirm the rated pressure value of the tested equipment before testing. Do not use it if it exceeds the range of the instrument. Also for DY517A, if the packed
    hoses does not match the pressure requirement, you can use suitable replacements for testing.
    6) Do not use and store the instrument in high temperature, high humidity, flammable, explosive and strong electromagnetic fields.
    7) Please do not change the instrument internal circuit, to avoid any damage of the instrument or danger occurring.
    8) Please wear qualified protective equipment to protect user during testing.
    9) Please use the instrument in a well-ventilated environment to prevent inhalation of toxic gases.
    Packing List:
    1* DY517 Refrigerantion Digital Manifold Gauge
    1* User manual
    Terms & Conditions
    Payment
    We accept payment via
    PAYPAL ONLY
    .
    Payment must be made within 4 days of auction closing. or an updaid case will be open on ebay automatically.
    Please contact us via ebay massage to list your special requests (color, packages, etc.) immediately you paid for the order.
    Shipping
    We arrange the shipment from Monday to Friday. Shipping fee includes packaging and handling fees.
    Items will be send out within 1 business day after Payment Verified (Available on business days only).
    Please check your ebay shipping address before payment, and make sure it contain a valid phone number because almost all shipping request phone number,
    we may hold the order if phone number is missing
    .
    If the item is from China, Tax is buyer's responsibility, we can declare a lwer price to reduce or avoid customs tax, but we don't take responsibility if buyer don't clear the customs. If the item is from US/UK/AU, I will pay the tax for you.
    Return
    Please contact us for a solution via ebay massage before open a return. Communication always is best way to solve problem.
    We accept any return in 30 or 60 days that we promise.
    If buyer return it just because buyer don't like it or bought a wrong item, it is buyer pay for return shipping fee.
    if item is defect or wrong when it. we will pay for the shipping fee after buyer show the shipping invoice.
    Please never return the parcel without agreement
    , if you don't get RMA NO. from us, it is no possible for us to get the parcel. and we will take no further auction for the return.
    Feedback
    We will automatically leave positive feedback to every buyer who completed the transaction.
    Please DO LEAVE us FOUR 5- Detailed Selling Rating (DSR) and give Positive feedback which may help a lot for our business development. Because the Ratings below 5 are equal to "You are NOT satisfied. Your recognition is our motivation in developing our small company and improving our service for each customer. It'll take you one minute only.
    If you're not satisfied with our goods or service, please write to us immediately so that we can help you out. Sincerely hope you do not leave us any negative or neutral feedback. Communication is very important, we believe we can resolve all the problem with each other.
    Terms & Conditions
    We are legal company and honese seller, will protect every customer's profit. Any thought, please feel free to contact us. We will give you the best advise.
    We welcome to answer any questions you have. Please send us a message through eBay and we will answer you within 24 hours.
    Our working time: 8:30 AM - 18:00 PM (Beijing Time GMT+8 ), Monday - Friday. (weekend and holidays excluded).