-40%
Refrigerant Digital Manifold Gauge Set HVAC Vacuum Pressure Leakage Tester R134A
$ 71.27
- Description
- Size Guide
Description
Store categorySign Up Now !
You may also like
Refrigerant Digital Manifold Gauge Set HVAC Vacuum Pressure Leakage Tester R134A
Product Description
Description:
AUTOOL LM120+ Digital Refrigeration Manifold is an auxiliary instrument for the installation, testing, and maintenance of refrigeration equipment such as air conditioners and cold storage. The instrument is capable of double pressure test, dual temperature test (need test clip, not include), digital readout, multi-unit switching, multi-mode function, and built-in refrigerant database.
This manifold gauge uses high-strength engineering plastics and flexible non-slip silicone design, the whole machine is solid and comfortable to hold. Built-in 32-bit digital processing unit and high-precision data acquisition unit, high data and stability.Large-size liquid crystal display, LCD backlight support, data display clear and easy to read, convenient light operation.Long-life valve switch, 1/4-inch standard interface design to ensure that the instrument's durability and versatility.
Feature:
1. [Evaporation Pressure&Tempe test]: The maximum pressure when the refrigerant changes from liquid to gas. The lowest temp when the liquid becomes gaseous.(The lower the pressure and temp of the evaporation are, the more efficient the refrigeration cycle and the greater the refrigeration capacity will do.)
2. [Condensing Pressure&Temp Test]: The minimum pressure when the refrigerant changes from gas to liquid, and the maximum temp when the gas changes to liquid. (The lower the pressure and temp of condensation are, the higher the efficiency of the refrigeration cycle and the greater the refrigerant capacity will do.)
3. [High/Low-pressure temperature test]: The temperature of the AUTOOL LM120+ Digital Refrigeration Manifold in the high/low-pressure pipelines of the air conditioning system.
4. [Pressure leakage test]: Calculate the pressure difference between the initial test pressure and the second test pressure to determine if the refrigerant is leaking.
5.[Type Setting&Observable window]: AUTOOL LM120/LM120+ Digital Refrigeration Manifold can be set according to the type of refrigerant that the car needs to fill; The refrigerant filing status can be observed through a visible window.
6.[Smart Digital Display]: The intelligent digital display of the test results of the pressure and temperature of the air conditioning system reduces the cost of time.
7.[Three Years Warranty, Lifetime Maintenance]: For damage caused by non-human factors, AUTOOL promises to resend parts for free within 3 years.
Specification:
Pressure test: gauge pressure
Pressure test unit: Kpa; Mpa; bar; inHg; PSI.
Pressure test range: 0 Kpa – 6000 Kpa
Pressure test resolution: 1 Kpa
Pressure test accuracy: +/- 0.5 %(FS)+ 5dgt
Pressure overload limit: 10000 Kpa (10 Mpa; 100 bar;)
Vacuum test: relative vacuum
Vacuum test unit: Kpa; Mpa; bar; inHg; PSI.
Vacuum test range: -101 Kpa – 0 Kpa
Vacuum test resolution: 1 Kpa
Temperature test unit: °C (Celsius), °F (Fahrenheit)
Temperature test range: -40°C–150°C (-40°F–302°F)
Temperature test resolution:
0.1°C (-40°C–99.9°C), 1°C (100°C–150°C)
0.1°F (-40°F–99.9°F), 1°F (100°F–302°F)
Temperature test accuracy: +/- 0.5 °C + 2dgt +/- 0.9 °F + 2dgt
Built-in 89 kinds of refrigerant NIST: According to American NIST standard
Power Supply: 4 X 1.5V (SIZE.AA / LR6) Battery not include
Dimensions: 170*110*50mm
Weight: about 950g
EC/EN61010-1 safety standards for design and production:
1) The pressure measured by the digtal manifold pressure tester is gauge pressure.
2) Pressure testing ranges from -101Kpa to 6Mpa (-0.1bar to 60bar).
3) The limit pressure is 10 Mpa (100 bar).
4) The maximum operating pressure of standard hose is 600 PSI ( approximate 4.13 Mpa, 41.3 bar ).
The limit pressure is 3000 PSI approximate 20.68 Mpa, 206.8 bar ).
5) Please confirm the rated pressure value of the tested equipment before testing.
Do not use it if it exceeds the range of the instrument. Also for DY517A, if the packed hoses does not match the pressure requirement, you can use suitable replacements for testing.
6) Do not use and store the instrument in high temperature, high humidity, flammable, explosive and strong electromagnetic fields.
7) Please do not change the instrument internal circuit, to avoid any damage of the instrument or danger occurring.
8) Please wear qualified protective equipment to protect user during testing.
9) Please use the instrument in a well-ventilated environment to prevent inhalation of toxic gases.
Package Include:
1x Refrigerantion Digital Manifold Gauge
1x User Manual (English)
2x Temperature Clip
3x Test Pipe
1x Pouch
Battery not include
Payment
Delivery details
Terms of sales
About us
Contact us
Payment
We accept payment through PayPal only, this is easy and the most preferred way.
Please kindly
make a payment within 3 days
after you won this item.
Please note your shipping address must match your PAYPAL address.
Delivery details
Item will
be shipped within 3-5 days
of receiving full payment.
We will ship your order to your PayPal Verified address provided.
Please verify your address and make sure that it is your current address before making your payment.
We do not include invoice with our shipments.If you need invoice,please leave us your email,we will send the invoice to your email.
We offer free domestic shipping via FedEx or UPS on every order if your order location is in our US warehouse.
Terms of sales
All our products are free and fast shipping.But this do not include the duties.According to ebay's rules,
it is buyer's responsibility to make clearance and pay for the import tax.
1. We provide 30 days return upon the buyer received the item.
2. We
ONLY
accept the return with all original package. Please make sure the item have
NO
man-made sabotage.
3. The buyer will be required to pay for the return shipping label if you changed your mind or no longer need the item(s) or found a better price.
4.
The buyer is responsible for the correctness of the shipping address.
If the package is returned to the sender due to the buyer's error (such as an insufficient address, delivery failure, forward failure, etc.), we will deduct the original shipping cost in the refund.
About us
We work for a Positive Feedback, and we would like to offer a great customer service. If you have any problem please leave us message at any time.
Business Hours 9:00AM to 6:00PM Monday to Friday.
Contact us
Send us a message on eBay and we will answer within 24h on business days.
Feedback